Came Standalone GSM Gateway Module RGSM001S - 806SA-0010
- Availability:
- In Stock
- Product Code:
- 806SA-0010
- Brand:
- Came
-
Quick delivery in EU & UK
-
Easy returns within 14 days
-
Always follow your orders
-
Professional tech assistance
Description
Standalone GSM Gateway module for remote management of CAME automations
with the dedicated system CAME CONNECT module 002RSE included. Description
RGSM001
(GSM Master with 868 MHz radio transmitter)
Module for the remote management of one or more automations
CAME, through CAMEConnect, equipped with 2 digital inputs
2 N.O. relay outputs, 868 MHz radio transmitter, 485
interface
and GSM card. P>
The device can be used as a
module
master and manage one or more slave modules (maximum 5) associated with it, which a
in turn they can manage one or more automations.
The device is equipped with an external wired antenna that
must not be removed.
In the case of connection to the CAME control panel equipped with CRP using terminal A-B-GND,
power the module only from terminals 2-10 of the panel itself.
Technical data
Type RGSM001
AC power supply (V) 12 ÷ 30
DC power supply (V) 12 ÷ 35
Consumption (mA) 200
Radio signal powers 869.5MHz (dBm) 14
869.5MHz radio signal range in free area (m) 100
GSM signal strengths EGSM - 900MHz (dBm) 33
GSM DCS signal strengths - 1800MHz (dBm) 30
Digital inputs (V DC max) 24
Relay outputs (V DC max) 30
Relay outputs (A max) 1
Maximum length of the cable connected to the relay outputs (m) ≤ 10
Maximum length of the cable connected to the output 485 (m) ≤ 1000
Operating temperature (° C) -20 ÷ 70
Connection of multiple automations
Connect the module to one of the electronic boards on the terminals
(10-2) with a PVC FROR cable 2 x 0.5 & nbsp; (max length 3 m) and perform a
RS-485 connection (in enter-exit mode)
on the terminals (A-B-GND) with a cable type UTP CAT5 - AWG24
maximum UTP cable length CAT5,1000 m.
If necessary, insert the RSE
card
(refer to the module compatibility table (*) and set a
device number for each card
& nbsp; (see function [peripheral number] in the manual
of the automation or control panel).
All the automations connected to the module must have Baud rate set to 38400
(see function [change COM speed]
in the automation or control panel manual).
(*) The module compatibility table is available at the following address:
http://www.cameconnect.net
came / docs / cameconnect_compliant_devices.html
Connection of non-CRP automations
Using the relay outputs it is possible to control up to one
maximum of 2 automations via CAMEConn