Domotime DC2SEM2L - Traffic light control unit 2 traffic lights with 2 lights
- Availability:
- In Stock
- Product Code:
- DC2SEM2L
- Brand:
- Domotime
-
Quick delivery in EU & UK
-
Easy returns within 14 days
-
Always follow your orders
-
Professional tech assistance
Description
DC2SEM2L -
Traffic light control unit 2 traffic lights with 2 lights
& Nbsp; p>
Control unit
traffic light to manage 2 traffic lights with 2 lights - 24 V and 230 V.
Cyclical time operation or with vehicle detectors.
& Nbsp; p>
The control unit universal electronics DC2SEM2L has been designed for the management of 2 traffic lights with 2 lights, in situations where driveway access regulation is necessary alternately (garages, parking lots, residences etc.). P>
The control unit can
operate with two operating logics, depending on the installation:
Operation without vehicle detection devices
& Nbsp; p>
The times of
alternation of red / green-green / red and red / red semaphore phases come
defined by the installer and are fixed, cyclical, regardless of the volume of the
incoming or outgoing traffic and the incoming or outgoing transit order.
In this case we will speak of "cyclic operation".
Operation with vehicle detection devices
The alternation times of the red / green-green / red semaphore phases
red / red are defined by the installer, but to activate the ignitions is
the detection of vehicles on the corresponding entrances (entry and exit)
through the special devices installed (photocells, radar, etc.). This
logic allows better management of the volume of incoming and outgoing traffic
and the order of entry and exit.
TECHNICAL DATA
230V power supply 50 Hz (5 VA)
Nr. 1 fuse for 24V ac line protection. 130 mA max.
Nr. 1 fuse for 160 mA line output protection
Nr. 1 fuse for auxiliary output protection 160 mA
Nr. 4 outputs a relay with dry changeover contact (230V 2A max)
Nr. 2 inputs for settable control devices N.O. or N.C.
Nr. 1 microswitch (Dip 2) for selecting N.O. inputs and N.C.
Nr. 1 Dip 1 microswitch for operation with detection device
Nr. 1 Trimmer (T1) for red light time adjustment (range from 5 to 120 seconds)
Nr. 1 Trimmer (T2) for green light time adjustment (range from 5 to 120 seconds)
Nr. 1 Trimmer (T3) for passage time adjustment (range 5 to 120 seconds) Nr. 5 LEDs for input and output status signaling.